Electrical Supplies & Power Infrastructure

Certified Electrical Supplies & Power Distribution Infrastructure Across Saudi Arabia

Single-source procurement of Medium & Low Voltage cables, ABB & Schneider switchgear, factory-assembled distribution boards, and cable raceway systems with verified MTC 3.1 certification.

View Technical Specifications
CAPABILITIES SCOPE

Scope of Specialized Electrical Procurement

Comprehensive electrical materials compliant with SASO regulations and Saudi Electricity Company (SEC) technical specifications.

01

MV & LV Power Transmission & Control Cables

Supply of copper and aluminum conductors for low voltage (LV 0.6/1kV) and medium voltage (MV up to 33kV) with XLPE/PVC insulation, Steel Wire Armor (SWA/AWA), and Low Smoke Zero Halogen (LSZH) fire-rated performance. Genuine supplies from Bahra Electric, Riyadh Cables Group, and Jeddah Cables Company.

Riyadh Cables • Bahra • Jeddah Cables
02

Switchgear, Industrial Circuit Breakers & Motor Control

Air Circuit Breakers (ACB), Molded Case Circuit Breakers (MCCB), Miniature Circuit Breakers (MCB), and Automatic Transfer Switches (ATS) from Schneider Electric, ABB, and Alfanar. Available breaking capacities up to 100kA with electronic trip units and digital metering.

Schneider Electric • ABB • Alfanar
03

Factory-Assembled Main Distribution Boards & MCCs

Main Distribution Boards (MDB) up to 4000A, Sub-Main Distribution Boards (SMDB), Final Panelboards, and Motor Control Centers (MCC) equipped with Variable Frequency Drives (VFDs) and soft starters rated IP54/IP65 for demanding industrial environments.

Assembled Panelboards • IP54 / IP65
04

Cable Management Containment & Raceway Systems

Heavy-duty hot-dip galvanized cable trays, cable ladders, wire mesh baskets, and insulated busbar trunking systems. Complete with fire-retardant Decoduct PVC conduits and fittings manufactured to BS EN 61537 and NEMA VE-1 international standards.

Cable Trays • Hot-Dip Galvanized • Decoduct
ENGINEERING BENCHMARKS

Technical Specifications & Engineering Standards

Comprehensive technical parameters assisting procurement officers and engineering consultants with BOQ spec matching.

01

Voltage Classes & Conductor Cross-Sections

Low Voltage (LV)600 / 1000 Volts (0.6/1kV) compliant with IEC 60502-1
Medium Voltage (MV)11 kV, 13.8 kV, 22 kV, 33 kV compliant with IEC 60502-2
Conductor Sizes1.5 mm² to 630 mm² (Single-core and Multi-core 3C / 4C)
Standard Cable Configurations3x185+95 mm², 3x240+120 mm², 4x95 mm², 4x120 mm², 4x16 mm²
02

Insulation, Armor & Fire Performance

Primary InsulationCross-linked Polyethylene (XLPE) rated 90°C continuous, or high-grade PVC
Mechanical ArmorGalvanized Steel Wire Armor (SWA), Steel Tape (STA), or Aluminum Wire Armor (AWA)
Fire Retardant StandardsIEC 60332-1, IEC 60332-3 Cat A/B/C, IEC 60754 Halogen-Free, IEC 61034 Low Smoke
Outer Sheath PropertiesUV Resistant, anti-termite, hydrocarbon and chemical resistant formulation
03

Regulatory Standards & Accreditations

Saudi StandardsFully compliant with Saudi Standards, Metrology and Quality Organization (SASO)
International NormsIEC 60502, IEC 60947 (Switchgear), BS 5467, BS 6724, IEEE 383
Major Utility ApprovalsAccepted on vendor lists for Saudi Aramco and Saudi Electricity Company (SEC)
Mill Test CertificationEvery consignment accompanied by original Mill Test Certificate (MTC EN 10204 3.1)
PROJECT APPLICATIONS

Target Sectors & Industrial Applications

Manufacturing Plants & Industrial Cities (MODON)

Powering automated assembly lines, production substations, motor control centers, and utility infrastructure in Jeddah, Riyadh, and Bahrah.

Power Generation & Utility Substations (SEC)

Supply of medium voltage feeder cables, power step-down transformers, Gas Insulated Switchgear (GIS), and ground grid protection.

Vision 2030 Megaprojects & Commercial Infrastructure

Supplying master contractors with bulk certified underground distribution cables, compact substations, and energy management panels.

Electromechanical & MEP Contracting Firms

Turnkey Bill of Quantities (BOQ) fulfillment with scheduled phased site deliveries synchronized with project execution milestones.

TECHNICAL FAQ

Frequently Asked Procurement Questions

Yes. In addition to full standard master wooden drums (500m and 1000m), we offer precision cable cutting tailored to your engineer’s cable schedule. This minimizes scrap and scrap handling costs on-site, with all cable ends weather-sealed with heat-shrink end caps.

Our commercial quotations are tied to the London Metal Exchange (LME) copper cash settlement price and official currency conversion rates. We issue clear formal quotations with defined validity windows, protecting project contractors from sudden cost volatility during client tender evaluations.

Yes, without exception. Every dispatch is accompanied by an original Mill Test Certificate (EN 10204 3.1) from the manufacturer detailing batch numbers, conductor resistance, elongation test records, insulation spark tests, and routine high-voltage withstand results.

From our logistics hub in Bahrah on the Old Makkah-Jeddah Highway corridor adjacent to major cable manufacturing facilities, standard cable sizes and switchgear components are dispatched same-day or within 24 hours to Jeddah MODON industrial cities, with scheduled dedicated freight to Rabigh, Yanbu, and Riyadh.

Ready to Submit Your Bill of Quantities (BOQ)?

Our engineering sales team matches exact technical specifications with factory inventories to issue official commercial proposals within 24 hours.

WhatsApp: 056 363 0366